Shelving, lockers, and utility furniture

Laboratory Support Furniture

Support furniture fills the spaces between primary benches and specialist equipment. Selection should reflect stored loads, staff use, cleaning, corrosion exposure, access, anchoring, and the instrument or operational task being supported.

Final materials, dimensions, performance requirements, and compliance criteria must be confirmed in the quotation and technical review.

Request a quotation
Adjustable steel laboratory storage rack

01

Configuration overview

  • Adjustable shelving and storage
  • Utility cabinets and personnel lockers
  • Worktable and balance-table discussions

02

Information to confirm

  • 01Stored item size and weight
  • 02Staff and task workflow
  • 03Floor, wall, and anchoring conditions
  • 04Cleaning and material exposure

03

Typical planning contexts

  • Laboratory stores
  • Gowning and staff support areas
  • Instrument and preparation rooms

Product planning

Decisions that shape the final configuration

Use these planning points to organize the room, equipment, service, and operating information needed before a configuration is confirmed.

01

Match furniture to the stored load

List item dimensions, unit and total shelf weight, loading method, access frequency, and whether restraints, doors, locks, or mobile handling equipment affect the layout.

02

Review task-specific support

For worktables or balance tables, provide the instrument data, vibration sensitivity, operating weight, user posture, utilities, and manufacturer installation requirements before choosing a support structure.

03

Confirm room and anchoring conditions

Check floor level, wall type, seismic or local anchoring requirements, aisle width, door swing, cleaning clearance, and delivery route before approval.

Technical brief

Configuration details to confirm

These fields provide a practical review framework rather than fixed model claims. Record the agreed selection in the quotation, drawings, and technical submittal before production.

Reference range
The source material includes adjustable steel shelving, steel utility cabinets, lockers, stainless worktables, and balance-table references.
Structure
Frame section, bracing, shelf supports, cabinet panels, hardware, finish, feet, and adjustable components are confirmed against the load and room conditions.
Load planning
Shelf and table loads, concentrated support points, loading method, stability, anchoring, and deflection criteria require project-specific confirmation.
Instrument support
Anti-vibration or balance-table requirements must follow the actual instrument, room vibration context, and manufacturer instructions rather than a generic furniture label.
Access and cleaning
Shelf spacing, door or locker layout, floor clearance, reach, lock requirements, and cleanable access are matched to the operating workflow.
Required submittals
Provide an item and load schedule, room plan, aisle and delivery constraints, instrument data where relevant, anchoring requirements, quantities, and destination.

Reference model guide

YOJIA inquiry models and reference parameters

Use these original YOJIA reference codes to compare common configurations and prepare an inquiry. They are planning identifiers, not copies of another manufacturer's models or fixed production guarantees.

Reference modelConfigurationReference dimensionsSelection notes
YJ-SR-1200Adjustable storage rack1200 × 500 × 2000 mmGeneral component or consumable storage with shelf count and loads confirmed.
YJ-SR-1800Wide adjustable storage rack1800 × 600 × 2000 mmWider rack requiring shelf-span, anchoring, aisle, and load review.
YJ-UC-900Laboratory utility cabinet900 × 500 × 1800 mmGeneral tools and supplies cabinet with configurable shelves and lock.
YJ-LK-900Laboratory locker900 × 500 × 1800 mmPersonnel storage reference with project-selected compartment and ventilation details.

Reference parameter range

Reference modules
900–1800 mm widths, 500–600 mm depths, and 1800–2000 mm heights; room and transport constraints govern final size.
Shelf arrangement
Shelf quantity, spacing, material, retaining edge, dividers, and access are selected from the stored-item schedule.
Load inputs
Provide total load, per-shelf load, point loads, centre of gravity, loading method, and future expansion; no capacity is implied by the model code.
Stability
Levelling, anchoring, bracing, wall condition, seismic or impact requirements, and aisle clearance require project review.
Cabinet and locker options
Doors, locks, labels, vents, garment rail, shelves, clean/dirty separation, and plinth are configurable.
Ordering rule
Approved drawings, load basis, anchoring responsibility, finish, and hardware define the supplied support furniture.

All dimensions are nominal planning references. Final materials, thicknesses, loads, ventilation criteria, fixtures, interfaces, compliance evidence, and supplied scope must be recorded in the approved quotation and technical documents.

PRODUCT VIEW

Reference configurations

Images show reference configurations. Confirm the exact supplied model, finish, dimensions, fixtures, and accessories in the final quotation.

Buyer questions

Before requesting a quotation

Clear project inputs help the team identify the right configuration and the details still requiring technical review.

01What is needed to select laboratory shelving?

Provide shelf dimensions, item sizes, weight per shelf, access frequency, material exposure, adjustment needs, restraint or anchoring requirements, and the room layout.

02Can a general worktable be used for a precision balance?

Not automatically. Instrument sensitivity, room vibration, support points, table mass and stiffness, isolation approach, and manufacturer instructions should be reviewed first.

03Are lockers and utility cabinets part of the laboratory package?

They can be included when the room schedule identifies their locations, users, internal arrangement, locks, ventilation, finishes, and any separation from controlled laboratory storage.

RFQ / Project inquiry

Discuss this product family

Share the room plan, quantity, destination, and technical requirements for a project-specific response.

Request a quotation